About Fire Door Inspection (IS 3614-1)
CDG provides fire door inspection as per IS 3614-1 standard.
CDG is a leading Inspection organization in India. CDG is an ISO 17020 accredited Inspection and ISO 17025 accredited testing Services in all over India.
IS: 3614 (Part I) 1966 expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 1960*. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.
1. SCOPE This standard lays down the requirements regarding materials and details of construction of steel plate, metal covered and rolling type of fire-check doors for the protection of openings in walls or floors to restrict the spread of fire within buildings whether from internal fire or from external fire.
2. TERMINOLOGY
2.0 For the purpose of this standard, the following definitions shall apply.
2.1 Single Fire-Check Door One door shutter constructed for fitting on one side to an opening.
2.2 Double Fire-Check Door Two single fire-check door shutters as defined in 2.1 for fitting one on each side to an opening.
3. TYPES
3.1 Fire-check door shall be of the following types
a) Steel plate doors,
1)) Metal covered doors, and
c) Rolling steel shutters.
4. SIZES
4.1 Steel Plate Doors and Metal Covered Doors The size of steel plate doors and metal covered doors shall suit the size of opening which shall neither exceed 5 m2 in area nor shall be more than 2 10 m in width or 2 75 m in height.
4.2 Rolling Steel Shutters The size of rolling steel shutters shall suit the size of doorway which shall neither exceed 5 m2 in area nor shall be more than 2 4 m in width or 2 10 m in height, measured between the faces of the reveals of opening or projecting jambs and for the floor of the opening to the underside of the barrel.
We at CDG are committed to improve business performance of our clients or customers with effective certification of management systems, inspection and verification and add value to the process/system during surveillance audits.
CDG has designed and implemented a certification of the management system modeled along the lines of National & International Standards.
CDG aims at providing independent, impartial, non-discriminatory assessment & certification via cost effective manner and accessible within defined and approved scope of certification.
Product details
| Location | India |
| Issue To Be Inspected | Fire Door Parameters & Features |
| Inspection Service For | Fire Door |
| Inspection Interval | One Time Requirement |
| Industry Type | Fire Door |
| Usage/Application | Industrial |
| Mode Of Report | Soft Copy |
| Inspection Method | Visual |
Comprehensive Fire Door AssessmentOur inspection covers every aspect of fire door safety, including structural integrity, functional hardware, proper sealing, and effective closing mechanisms. We inspect all material types-wood, steel, and composite-ensuring that each door meets IS 3614-1 and BIS/local fire safety norms.
Certified On-Site Inspection by ExpertsTrained and certified inspectors conduct all assessments on-site, utilizing precise measuring tools, gap gauges, and thermal detectors when necessary. Our team delivers a professional and thorough evaluation based on the latest compliance and industry standards.
Detailed Documentation & ReportingFollowing inspection, we provide comprehensive documentation: customized checklists, photographic evidence, and official compliance certificates. Clients receive a detailed assessment report, including findings, recommendations, and necessary rectification advice within 24-48 hours.
Support for Rectification and ComplianceBeyond inspections, our service offers consultancy and technical support for post-inspection rectification. We assist clients in interpreting findings and implementing effective solutions to ensure ongoing compliance and safety of fire doors.
FAQ's of Fire Door Inspection (IS 3614-1):
Q: What does a Fire Door Inspection (IS 3614-1) involve?
A: The inspection includes a thorough evaluation of fire doors' structural integrity, hardware, frame, seals, and closing mechanisms. This encompasses both visual and functional checks, ensuring all aspects comply with IS 3614-1 and BIS/local fire safety regulations.
Q: How long does a fire door inspection take, and what determines its duration?
A: The duration of the inspection depends on the number of fire doors and the specific site conditions. Larger facilities or those with difficult access may require additional time. Our team strives to minimize disruption while ensuring a comprehensive evaluation.
Q: What documentation will I receive after the inspection?
A: You will receive a detailed report featuring completed checklists, photographic evidence, and compliance certificates. This report outlines the condition of each inspected door, highlights any compliance gaps, and provides recommendations for rectification.
Q: Who conducts the fire door inspections?
A: Inspections are performed by trained and certified fire door inspectors with expertise in IS 3614-1 standards. Our professionals are skilled in assessing wood, steel, and composite fire doors across various building types.
Q: How can I prepare my premises for fire door inspection?
A: Ensure full access to all fire doors to be inspected and gather any previous inspection reports if available. This preparation enables a seamless inspection process and helps our inspectors deliver accurate and comprehensive findings.
Q: When and how often should fire door inspections be conducted?
A: Fire door inspections should typically be carried out annually or as specified by compliance requirements and local fire safety regulations. Regular inspections help maintain compliance and enhance occupant safety.
Q: What are the benefits of a professional fire door inspection service?
A: Professional inspections ensure that all fire doors function correctly and meet legal safety standards, reducing liability and enhancing occupant protection. Our service also includes post-inspection consultancy for rectification to maintain ongoing compliance.