Call Us: +919643077962
Ingress Protection (IP) Testing in Bengaluru

Ingress Protection (IP) Testing in Bengaluru

Product Details:

X

Product Description

Ed circulating talcum powder in a dust chamber for 8 hours with theexposure time being determined by the testing conditions for the specific item.This testing is performed with a maximum pressure of 20 mbar inside the itemunder test, and with a maximum abstraction rate of 60 volumes per hour.ProtectionIndex Against Water entry,This test specify the second digit of the ProtectionIndex ( IPXI, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IPX8), meaning protection againstwater entry into the fixture according to the) BS EN 60598 1 IEC 60598 1, IEC60529.1. IPX1,Protected against dripping water,Specification, Theenclosure is exposed to dripping water with a flow rate of 1 mm per min for 10minutes. Acceptance for Class IP X1 requires no water to have penetrated intothe item in such a quantity, or in such a position as to prevent satisfiedoperation of the item or to present a safety risk.2. IPX2,Protection against dripping water at tilted to 15 degrees,Specification, The enclosure is exposed to drippingwater during 4 positions for 2.5 minutes, with a flow rate of 3 mm per min. Theenclosure is tested in four fixed positions of 15 degree from normal positionAcceptance for the Class IP X2 requires no water to have penetrated into theitem in such a quantity or in a position as to prevent the satisfactoryoperation of the item or to present a safety risk.3. IPX3,Protected againstspraying water,Specification, The enclosure is exposed to water sprayfrom a oscillated tube with each spray jet give a flow rate of 0.07 l per min,for 10 minutes. Alternative, a standardized spray nozzle, producing a spray of10 l per min may be used. If this spray nozzle is used, the exposed time is 1minperm square with a minimum time of of five minutes Regardless to the type oftest equipment, water spraying is limited to  60 from the Acceptance for Class IP X3requires no water to have penetrate the item in a quantity, or in such aposition as to prevent satisfactory operation of the item or to present asafety risk.4. IPX4,Protected against splashing water,Specification, The enclosures exposed to water sprayfrom an oscillated tube with each spray nozzle give a flow rate of 0.07 l per min,for 10 minutes Alternative, a standardized spray nozzle, producing a spray of10 l per min may be used for the spray nozzle is used in the exposure time is 1minperm square , with a minimum time of five minute for water is splashedagainst the enclosure from all the directions. Acceptance for Class IP X4requires no water to have penetrate into the item in such a quantity, or insuch a positions to prevent satisfactory operation of the item or to present asafety risk.5. IPX5,Protected against water jets,Specification, The enclosure is subjected to a jet ofwater from a nozzle 6,3 mm internal diameter at a distance of 2,5 to 3 m fromthe EUT under testing. The water flow rate 12,5 l per min is applied for timeof 1 minperm square with a minimum test duration of 3 minutes. Acceptance forClass IP X5 requires no water to have penetrate into the item in such aquantity or in such a position as to prevent satisfactory operation of the itemor to present a safety risk.6. IPX6,Protected against powerfulwater jets,Specification, The enclosure issubjected to a jet of water from a nozzle of 12,5 mm diameter at a distance of2,5 to 3 m from the EUT under test. The water flow rate is 100 l per minapplied for a time of 1 minperm square, with a minimum of 3 minutes. Acceptancefor Class IP X6 requires no water to have penetrate into the item in such aquantity or in such a position as to prevent satisfactory operation of the itemor to present a safety risk.7. IPX7,Temporary immersion in thewater,Specification, The test is made by complete immersionof the EUT in water in its service position.The enclosure is immersed to thedepth of 1 meter with the duration time of 30 minutes. Acceptance for Class IPX7 requires no water to have penetrate into the item in such a quantity, or insuch position to prevent satisfactory operation of the item or to present asafety risk.8. IPX8,Continuous immersion in water,Specification, The test is made by complete immersingthe EUT in water.Test conditions are subject to agreement between the companythe and user. Acceptance for the Class IP X8 requires no water to havepenetrate into the item in a quantity or in such a position to preventsatisfactory operation of the item or to present a safety risk.

Enter Buying Requirement Details
Email Id
Mobile number


Back to top
CDG INSPECTION LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.